History file for TED2 V 24.51 2024-05-08 OS Update Bugfix: Don't switch off display, if external power is supplied Command to enter bib via USB Configurable bib suggestion V 24.21 2024-02-15 Improved the manipulation and displaying of the channel state Extended and corrected the protocol printing Fixed wrong pulse hold message when synchronizing manually V 24.12 2024-01-31 If a printer is connected, setting changes and synchronisation are logged Fixed to handle deleted triggers when switching on the TED2 Setting the radio channel in the radio module is more robust Show state during executing "send memory" menu Corrected typo in synchronize menu Added more features when deleting a trigger Adapted the sequence of printing trigger with RSM command to fulfill skiing regulations V 23.B1 2023-11-10 Don't turf off display when device is powered Optimized GPS initialization at start up Optimized gps synchronization and calibration Menu entry to print all stored triggers V 23.A2 2023-10-05 Bugfix with command responses (like NSF?, DEVINFO?,..). Bug was only in V23.A1 V 23.A1 2023-10-04 Nested trigger transmission for speed measurement Enter a SYNM sync time via menu Report entered bib via USB (only RX) Bugfix in USB host connection when using a P6 with external power supply Improve GPS icon on longer GPS module startup time Improve battery icon V 23.92 2023-09-26 Sync time: handling improved,bug fixed, partially codereview done V 23.91 2023-09-15 Sync time can be enteres manually by menu V 23.83 2023-08-30 Bugfix: battery icon wasn't painted on each entering of main screen V 23.82 2023-08-30 STN* feature for main screen and scroll mode Fast trigger transmission at high tx power fixed STD command set tx power and channel to default New commands: RSSI?, RFCHANNEL?, RFCHANNEL:XXX, TXPOWER?, TXPOWER:X V 23.73 2023-07-25 Bugfix on outputting triggers on RS232 Additional monitoring of GPS interface Bugfix: trigger received via radio weren't printed V 23.72 2023-07-18 Increase the field test priority (interrupts data transmission and all screens) Bugfix in memo mode: actualized trigger weren't removed from the list Bugfix: Battery wasn't charged under specific circumstances Bugfix: Via radio received trigger weren't printed on P6 at RX Bugfix: If no usb was connected, no trigger were printed on RS232 Bugfix: Missing resends at TX fixed STD clears all trigges. synchronization will only be reset if it wasn't yet GPS V 23.71 2023-07-11 Bugfix on charging battery V 23.63 2023-06-16 Bugfix in usb device connection Bugfix in P6 support V 23.62 2023-06-16 Bugfixing and improving the usb connectivity for device and host External power detection for P6 printer RSM command: ordering of trigger corrected support field test during data transmission bugfixes of data transmission for special cases V 23.61 2023-06-14 A field test has top priority in radio transmission Serial data and resends of triggers are interrupted by the field test The ESC key is deactivated during the trigger reset Bugfix: Return of the resend menu to the info state after the end of the switch-off window Bugfix that the last SystemState switching command was not completely transmitted at the end of the field test Bugfix that the last SystemState switch command at the end of the field test was not transmitted due to an already occupied DMA process V 23.51 2023-05-25 (test version for Rev4) Smoothing of the operating voltage by weighting the old measured value and the new voltage measurement. Radio frequency, memory consumption of triggers and transmitter power are new in the Info Display Bugfix that wrong characters were shown in the Info Display Bugfix that the serial number was not shown in the Info display Command to set the minimum trigger length Radio module in the transmitter is no longer set to power saving mode after power on Bugfix that it was no longer possible to scroll in the channel settings menu Triggers can be printed on the printer Serial interface is configured according to the device type Bugfix that parts of the menu cursor are deleted Menu entry TED1 Mode renamed to TED-RX Table of resend times corrected Bugfix at USB OTG feature VBus is switched off at an operating voltage of less than 3.6 V Continuous VCC measurement at intervals of approx. 156 mSec RSSI measurement at intervals of 4 mSec and averaged during the transmission process CC module now reports changes via interrupt The last deviation is now also available when the GPS is asleep. Logging must now be explicitly activated Sync status and device type removed from the Info Display V 23.41 2023-04-17 TED1 compatibility mode Bugfix: corrected the VCC value in the system state Bugfix: receiver checks all received data additionally support P6 printer via USB Improvements in USB host and device support V 23.31 2023-03-29 Bugfix in USB handling Show empty TX battery at RX Adapted the default settings Optimized the RSSI measurement Accept all trigger resends after ClearMemory Corrected the baudrates at automatic baudrate selection activate watchdog Improved the scroll mode V 23.22 2023-02-14 EMV Test: Maximum output power (500mW) V 23.22 2023-02-07 EMV Test: Bugfix in stop sending system states EMV Test: display GPS info V 23.21 2023-02-07 Bugfix in trigger transmission when trigger occured simultaneously Automatic baudrate switching Receiver must be synchronized to physically trigger a received trigger EMV Test: turn fieldstrength test on/off V 23.11 2023-01-31 Initial version for TED2 Ref.2